نمایش 19–27 از 33 نتیجه

نمایش 9 24

ترانسمیتر فشار ZHYQ PT124B-212

GENERAL INFORMATION
Brand

ZHYQ

Origin

China

Series

ZHYQ – PT124B-212

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Diffused silicon piezoresistive

Varieties

Explosion Proof (EX), Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar]

Pressure Range

-1 … 0 bar, 0 … 1 to 0 … 600 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

600

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

8702.3

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.2 %FS, ≤ ± 0.25 %FS, ≤ ± 0.5 %FS

Accuracy Details

Including Linearity, Repeatability & Hysteresis

Non-linearity

≤ ± 0.2 %FS

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.2 %FS

Long Term Stability Details

per 1 year

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

NO

Adjustability Details

N/A

Resolution

N/A

Sensitivity

N/A

Response Time

< 5 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 0 … 5 VDC, 0.5 … 4.5 VDC Ratiometric, 1 … 5 VDC, 4 … 20 mA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-20

Media Temperature [°C] [Max]

+80

Ambient Temperature [°C] [Min]

-20

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

0

Compensated Temperature [°C] [Max]

+75

Ingress Protection

N/A

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

1/2" NPT, 1/4" NPT, G 1/2", G 1/4", M12x1.5, M20x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel (304), Stainless steel (316L)

Diaphragm / Sensor Material

Stainless steel (304), Stainless steel (316L)

Filling Fluid

N/A

Seal

N/A

Hygienic Version

NO

Electrical Connection

Bendix, Cable gland, Cable outlet, DIN EN 175301-803-A, M12x1

Electrical Connection Details

Hirschman(DIN), M12(4pins) , 5pins , gland cable, direct cable optional

Display

NO

Display Details

N/A

Weight

N/A

TESTS / APPROVALS
Scope Approvals

CE / European Community, CMC (China Metrology Certification) / China, NEPSI / China, RCQM / Global

Ship Approvals

N/A

Explosion Protection

N/A

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Gas pressure measurement, Hydraulic systems, Hydrostatic level measurement, Machine tools, Test and measurement

ترانسمیتر فشار اشکرافت A4

GENERAL INFORMATION
Series / Product

Series

Brand

ASHCROFT

Origin

USA

Series

ASHCROFT – A4

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

N/A

Varieties

Absolute, Explosion Proof (EX), Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[psi]

Pressure Range

-14.7 … 0 to -14.7 … 60 psi, 0 … 1.5 to 0 … 10000 psi / -1 … 0 bar to -1 … 4.1 bar, 0 … 100 mbar to 0 … 689.5 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

689.5

Pressure Range [psi] [Min]

-14.7

Pressure Range [psi] [Max]

10000

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.25 %FS, ≤ ± 0.5 %FS, ≤ ± 1 %FS

Accuracy Details

Accuracy Class (Includes non-linearity): ±0.25%, ±0.5%, ±1.0% of span Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.25 %FS

Long Term Stability Details

≤±0.25% span/year at reference conditions

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

Available with externally adjustable zero and span access.

Resolution

N/A

Sensitivity

N/A

Response Time

< 2 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA

Output Signal Details

■ 4 … 20 mA / 2-wire

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+125

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+125

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+125

Compensated Temperature [°C] [Min]

-20

Compensated Temperature [°C] [Max]

+85

Ingress Protection

IP65, NEMA 4X

Vibration Resistance

Random Vibration: 10g RMS, 20-2,000Hz, Sweep Vibration: 50-2,000Hz, 5g peak

Shock Resistance

100g Peak, 11ms

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, 1/4" NPT, 1/8" NPT, 7/16"-20 UNF, G 1/2", G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel (316L)

Diaphragm / Sensor Material

Stainless steel (17-4 PH), Stainless steel (316L)

Filling Fluid

N/A

Seal

N/A

Hygienic Version

NO

Electrical Connection

Bendix, Cable outlet, DIN EN 175301-803-A, M12x1, Pigtail Cable

Electrical Connection Details

■ Integral Cable (Pigtail) ■ Hirschmann® Style Form A DIN 43650-A ■ 4-Pin Bendix® Style

Display

NO

Display Details

N/A

Weight

N/A

TESTS / APPROVALS
Scope Approvals

CE / European Community, CSA / Canada, FM / USA

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Alternative energy projects, Gas pressure measurement, Natural gas compression and transfer control, Oil field equipment, Upstream oil and gas production

سنسور فشار ویکا IS-3

GENERAL INFORMATION
Series / Product

Series

Brand

WIKA

Origin

Germany

Series

WIKA – IS-3

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

N/A

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], Optional: [psi], [inHg]

Pressure Range

-1 … 0 to -1 … 24 bar, 0 … 100 mbar to 0 … 6000 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

6000

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

87022.6

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.25 %FS, ≤ ± 0.5 %FS

Accuracy Details

Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2)

Non-linearity

≤ ± 0.2 %FS

Non-linearity Details

per BFSL (IEC 61298-2)

Long Term Stability

≤ ± 0.2 %FS

Long Term Stability Details

@ Reference conditions, per 1 year

TC Sensitivity

≤ ± 0.2 %FS/10K

TC Zero Point

■ ≤ ± 0.2 %FS/10K ■ ≤ ± 0.4 %FS/10K

Adjustable

YES

Adjustability Details

Zero and span adjustable (± 5 %) through potentiometer within the instrument

Resolution

N/A

Sensitivity

N/A

Response Time

< 10 ms, < 2 ms

Response Time Details

Settling time: ≤ 2 ms, ≤ 10 ms for medium temperatures below -30 °C [-22 °F]

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-20

Media Temperature [°C] [Max]

+80

Ambient Temperature [°C] [Min]

-20

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-20

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

0

Compensated Temperature [°C] [Max]

+80

Ingress Protection

IP65, IP67, IP68, IP69K

Vibration Resistance

please refer to datasheet

Shock Resistance

please refer to datasheet

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Flush Diaphragm, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, 1/4" NPT, 7/16"-20 UNF, 9/16"-18 UNF, G 1", G 1/2", G 1/4", G 3/8", M16x1.5, M20x1.5, R 1/4", R 3/8"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel (316L), Stainless steel 1.4534 (13-8 PH), Stainless steel 1.4571 (316Ti)

Diaphragm / Sensor Material

Stainless steel (316L), Stainless steel 1.4534 (13-8 PH), Stainless steel 1.4571 (316Ti)

Filling Fluid

Halocarbon oil, Synthetic oil, Without

Seal

Copper, EPDM, FKM, FPM, NBR, Stainless steel

Hygienic Version

YES

Electrical Connection

Bayonet, Cable outlet, DIN EN 175301-803-A, Field case, M12x1, M16x0.75

Electrical Connection Details

N/A

Display

NO

Display Details

N/A

Weight

N/A

TESTS / APPROVALS
Scope Approvals

3-A (Sanitary Standard) / USA, ATEX / Europe, BelGIM / Belarus, CE / European Community, CRN / Canada, CSA / USA and Canada, EAC / Eurasian Economic Community, FM / USA, GOST / Russia, IEC / Worldwide, IECEx / Worldwide, INMETRO / Brazil, KazInMetr / Kazakhstan, KCs (KOSHA) / South Korea, MTSCHS / Kazakhstan, NEPSI / China, PESO / India, UkrSEPRO / Ukraine, Uzstandard / Uzbekistan

Ship Approvals

DNV-GL / International

Explosion Protection

Dust Explosion Protection Through Housing "t", Intrinsic Safety "i", Non-incendive "n"

EX Zone

Zone 0, Zone 1, Zone 2, Zone 20, Zone 21, Zone 22

Other Approvals

RoHS

SIL Qualification

SIL 2

INDUSTRIES / APPLICATIONS
Application

CIP (Clean-In-Place), Gas pressure measurement, Hydrogen pressure measurement, Oxygen pressure measurement

ترانسمیتر فشار کلر KELLER – 35 X Ed

GENERAL INFORMATION
Series / Product

Series

Brand

KELLER

Origin

Switzerland

Series

KELLER – 35 X Ed

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar]

Pressure Range

■ Vented Gauge: -1 … 1 to -1 … 30 bar ■ Sealed Gauge: 0 … 100 mbar to 0 … 100 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

100

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

1450.4

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.03 %FS, ≤ ± 0.2 %FS

Accuracy Details

Linearity (BFSL) + hysteresis + repeatability

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS, 1 mbar

Long Term Stability Details

0.1 %FS typ. (FS > 1 bar), 1 mbar typ. (FS ≤ 1 bar)

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ Interface: RS485 ■ Protocol: KELLER Bus and MODBUS RTU. The devices can be configured (scale analog output, switch units, change filter settings, zeroing, etc.)

Resolution

N/A

Sensitivity

N/A

Response Time

< 5 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 4 … 20 mA, RS-485, RS-485 / Modbus RTU

Output Signal Details

■ 4 … 20 mA / 2-wire ■ 0 … 10 V / 3-wire ■ Protocol: KELLER Bus and MODBUS RTU

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-30

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-30

Ambient Temperature [°C] [Max]

+100

Storage Temperature [°C] [Min]

-30

Storage Temperature [°C] [Max]

+100

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP50, IP65, IP68

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Flush Diaphragm

Process Connection Male/Female

Male

Process Connection

1/2"-14 NPT, G 1/2", G 3/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Gold-plated (Au), Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Diaphragm / Sensor Material

Gold-plated (Au), Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Filling Fluid

Fluorized oil, Olive oil, Silicone oil

Seal

Viton®

Hygienic Version

NO

Electrical Connection

Cable outlet

Electrical Connection Details

PUR-cable, length 2 m (with PE-sheath and reference tube for gauge). Others on request.

Display

NO

Display Details

N/A

Weight

Approx. 200 g

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community

Ship Approvals

N/A

Explosion Protection

Flameproof Enclosure "d"

EX Zone

Ex db IIC T6 to T4, II 2 G, LCIE 03 ATEX 6082 X

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Gas pressure measurement, Hydraulic systems, Laboratory and test, Oxygen pressure measurement, Pasty media, Pressure monitoring in the hazardous areas, Test benches, Vacuum pressure measurement, Viscous media

ترانسمیتر فشار کلر KELLER – 33 X Ed

GENERAL INFORMATION
Series / Product

Series

Brand

KELLER

Origin

Switzerland

Series

KELLER – 33 X Ed

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive

Varieties

Absolute, Explosion Proof (EX), High Accuracy

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar]

Pressure Range

■ Vented Gauge: -1 … 1 to -1 … 30 bar ■ Sealed Gauge: 0 … 100 mbar to 0 … 300 bar ■ Absolute: 0 … 1 to 0 … 300 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

300

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

4351.1

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.03 %FS, ≤ ± 0.2 %FS

Accuracy Details

Linearity (BFSL) + hysteresis + repeatability

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS, 1 mbar

Long Term Stability Details

0.1 %FS typ. (FS > 1 bar), 1 mbar typ. (FS ≤ 1 bar)

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ Interface: RS485 ■ Protocol: KELLER Bus and MODBUS RTU. The devices can be configured (scale analog output, switch units, change filter settings, zeroing, etc.)

Resolution

N/A

Sensitivity

N/A

Response Time

< 5 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 4 … 20 mA, RS-485, RS-485 / Modbus RTU

Output Signal Details

■ 4 … 20 mA / 2-wire ■ 0 … 10 V / 3-wire ■ Protocol: KELLER Bus and MODBUS RTU

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-30

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-30

Ambient Temperature [°C] [Max]

+100

Storage Temperature [°C] [Min]

-30

Storage Temperature [°C] [Max]

+100

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP50, IP65, IP68

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

G 1/2", G 1/4", G 3/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Gold-plated (Au), Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Diaphragm / Sensor Material

Gold-plated (Au), Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Filling Fluid

Fluorized oil, Olive oil, Silicone oil

Seal

Viton®

Hygienic Version

NO

Electrical Connection

Cable outlet

Electrical Connection Details

PUR-cable, length 2 m (with PE-sheath and reference tube for gauge). Others on request.

Display

NO

Display Details

N/A

Weight

Approx. 200 g

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community

Ship Approvals

N/A

Explosion Protection

Flameproof Enclosure "d"

EX Zone

Ex db IIC T6 to T4, II 2 G, LCIE 03 ATEX 6082 X

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Gas pressure measurement, Hydraulic systems, Laboratory and test, Oxygen pressure measurement, Pressure monitoring in the hazardous areas, Test benches, Vacuum pressure measurement

ترانسمیتر فشار هوبا کنترل مدل 525

GENERAL INFORMATION
Series / Product

Series

Brand

Huba Control

Origin

Switzerland

Series

Huba Control – 540

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Ceramic measuring cell

Varieties

Explosion Proof (EX), Low Pressure

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar], [psi], [MPa], [kPa]

Pressure Range

0 … 0.05 to 0 … 0.6 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

0.6

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

8.7

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.35 %FS, ≤ ± 0.7 %FS

Accuracy Details

■ bei 25 ºC, incl. zero point, full scale, linearity, hysteresis and repeatability ■ fs

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.25 %FS

Long Term Stability Details

Long term stability acc. IEC EN 60770-1

TC Sensitivity

≤ ± 0.07 %FS/10K

TC Zero Point

≤ ± 0.07 %FS/10K

Adjustable

NO

Adjustability Details

N/A

Resolution

< 0.1% FS

Sensitivity

N/A

Response Time

< 150 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 0 … 5 VDC, 0.5 … 4.5 VDC Ratiometric, 4 … 20 mA

Output Signal Details

■ 4 … 20 mA (2 wire) ■ Intrinsic safety 4 … 20 mA (2-wire) ■ 0 … 5 V (3 wire) ■ 0 … 10 V (3 wire) ■ ratiom. 10 … 90%(3 wire)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

YES

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-25

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-25

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP 65, IP67

Vibration Resistance

Vibration nach IEC 68-2-6: 20 g, 15 … 2000 Hz, 15 … 25 Hz with amplitude ± 15 mm, 1 Octave/min. all 3 directions, 50 constant load

Shock Resistance

Shock acc. IEC 68-2-27: 50 g, 6 ms half sine wave, all 6 directions, free fall from 1 m on concrete (6x)

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/4"-18 NPT, G 1/2", G 1/4", G 1/8", R 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

Ceramic, Al2O3 (99.6 %)

Filling Fluid

Without

Seal

EPDM, FPM, NBR

Hygienic Version

NO

Electrical Connection

DIN EN 175301-803-A, DIN EN 175301-803-C, M12x1, Swift Connector

Electrical Connection Details

■ Connector DIN EN 175301-803-A IP65 ■ Connector DIN EN 175301-803-C (Industrial standard 9.4 mm) IP65 ■ Connector M12x1 IP67 ■ Swift connector without or with cable 1.5 / 2 / 3 / 5 m (PVC spez.) IP67

Display

NO

Display Details

N/A

Weight

Approx. 120 g

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, EAC / Eurasian Economic Community, IECEx / Worldwide, UL / Global

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i"

EX Zone

Zone 0, Zone 1, Zone 20, Zone 21

Other Approvals

RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Air conditioning systems, Hydrostatic level measurement, Leak testing

ترانسمیتر فشار دیافراگمی دانفوس MBS 4510

GENERAL INFORMATION
Series / Product

Series

Brand

Danfoss

Origin

Denmark

Series

Danfoss – MBS 4510

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transducer

Technology (Measuring Principle)

N/A

Varieties

Absolute, Explosion Proof (EX), Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar]

Pressure Range

-250 … 500 mbar, 0 … 250 mbar to 0 … 25 bar

Pressure Range [bar] [Min]

-0.25

Pressure Range [bar] [Max]

25

Pressure Range [psi] [Min]

-3.6

Pressure Range [psi] [Max]

362.6

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.2 %FS, ≤ ± 0.5 %FS

Accuracy Details

■ incl. non-linearity, hysteresis and repeatability ■ ≤ ± 0.2% FS (typ.), ≤ ± 0.5% FS (max.)

Non-linearity

≤ ± 0.2 %FS

Non-linearity Details

Best fit straight line (BFSL)

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

■ ≤ ± 0.4 %FS/10K ■ ≤ ± 0.35 %FS/10K ■ ≤ ± 0.2 %FS/10K

TC Zero Point

■ ≤ ± 0.4 %FS/10K ■ ≤ ± 0.3 %FS/10K ■ ≤ ± 0.2 %FS/10K

Adjustable

YES

Adjustability Details

■ Zero point adjustment: 0 – 0.25 to 0 – 10 bar (-5 – 20% FS), 0 – 16 to 0 – 25 bar (-5 – 10% FS) ■ Span adjustment: 0 – 0.25 to 0 – 25 bar (-5 – 5% FS)

Resolution

N/A

Sensitivity

N/A

Response Time

< 4 ms

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA

Output Signal Details

4…20 mA (two wire transmission)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

YES

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-10

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-25

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

0

Compensated Temperature [°C] [Max]

+80

Ingress Protection

IP 65

Vibration Resistance

■ Sinusoidal: 15.9 mm-pp, 5 Hz – 25 Hz / 20 g, 25 Hz – 2 kHz (IEC 60068-2-6) ■ Random: 7.5 grms, 5 Hz – 1 kHz (IEC 60068-2-64)

Shock Resistance

■ Shock: 500 g / 1 ms (IEC 60068-2-27) ■ Free fall: 1 m (IEC 60068-2-32)

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

G 1"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

Stainless steel 1.4404 (316L)

Filling Fluid

N/A

Seal

NBR

Hygienic Version

NO

Electrical Connection

DIN EN 175301-803-A

Electrical Connection Details

Plug; Pg 9 (EN 175301-803-A)

Display

NO

Display Details

N/A

Weight

Approx. 400 g

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / USA and Canada, GOST / Russia, PED / Europe, PZH / Poland, UL / Global

Ship Approvals

N/A

Explosion Protection

Non-incendive "n"

EX Zone

Zone 2

Other Approvals

China RoHS, RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Filling and packing machinery, Potentially hazardous areas, Pressure monitoring in the hazardous areas, Process technology, Viscous media

ترانسمیتر فشار دانفوس MBS 3000

GENERAL INFORMATION
Series / Product

Series

Brand

Danfoss

Origin

Denmark

Series

Danfoss – MBS 3000

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transducer

Technology (Measuring Principle)

N/A

Varieties

Absolute, Explosion Proof (EX)

MEASURING RANGES
Reference Pressure

Absolute

Pressure Unit

[bar]

Pressure Range

0 … 1 bar to 0 … 600 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

600

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

8702.3

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.5 %FS, ≤ ± 1 %FS

Accuracy Details

■ incl. non-linearity, hysteresis and repeatability ■ ≤ ± 0.5% FS (typ.), ≤ ± 1.0% FS (max.)

Non-linearity

≤ ± 0.2 %FS

Non-linearity Details

Best fit straight line (BFSL)

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

■ ≤ ± 0.1 %FS/10K ■ ≤ ± 0.2 %FS/10K

TC Zero Point

■ ≤ ± 0.1 %FS/10K ■ ≤ ± 0.2 %FS/10K

Adjustable

NO

Adjustability Details

N/A

Resolution

N/A

Sensitivity

N/A

Response Time

< 4 ms

Response Time Details

Liquids with viscosity < 100 cSt: < 4 ms

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 0 … 5 VDC, 0.5 … 4.5 VDC Ratiometric, 1 … 10 VDC, 1 … 5 VDC, 1 … 6 VDC, 4 … 20 mA

Output Signal Details

Ratiometric output signal: 10-90% of supply voltage (4.5 – 5.5 V DC)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

YES

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-50

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

0

Compensated Temperature [°C] [Max]

+80

Ingress Protection

IP65, IP67, IP69

Vibration Resistance

■ Sinusoidal: 15.9 mm-pp, 5 Hz – 25 Hz / 20 g, 25 Hz – 2 kHz (IEC 60068-2-6) ■ Random: 7.5 grms, 5 Hz – 1 kHz (IEC 60068-2-64)

Shock Resistance

■ Shock: 500 g / 1 ms (IEC 60068-2-27) ■ Free fall: 1 m (IEC 60068-2-32)

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

1/2"-14 NPT, 1/4"-18 NPT, G 1/2", G 1/4", G 3/8", M18x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

Stainless steel 1.4404 (316L)

Filling Fluid

N/A

Seal

NBR

Hygienic Version

NO

Electrical Connection

AMP, Bayonet, Cable outlet, DIN EN 175301-803-A, M12x1

Electrical Connection Details

Refer to the datasheet

Display

NO

Display Details

N/A

Weight

Approx. 200 … 300 g

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community

Ship Approvals

N/A

Explosion Protection

Non-incendive "n"

EX Zone

Zone 2

Other Approvals

China RoHS, RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Booster pump, Hydraulic systems, Mobile hydraulics, Water pressure control system

ترانسمیتر فشار اکسترودر ZHYQ مدل PT124B-123

GENERAL INFORMATION
Series / Product

Series

Brand

ZHYQ

Origin

China

Series

ZHYQ – PT124B-123T

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transducer

Technology (Measuring Principle)

Strain gauge

Varieties

Explosion Proof (EX), Melt Pressure Sensor

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar], [psi], [MPa]

Pressure Range

0 … 35 bar to 0 … 1500 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

1500

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

21755.7

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.5 %FS

Accuracy Details

Including Linearity, Repeatability & Hysteresis

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

Zero and full span can be adjusted with screwdriver

Resolution

N/A

Sensitivity

N/A

Response Time

N/A

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 0 … 5 VDC, 4 … 20 mA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

0

Media Temperature [°C] [Max]

+350

Ambient Temperature [°C] [Min]

N/A

Ambient Temperature [°C] [Max]

N/A

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

N/A

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Rigid & Flexible Stem

Process Connection Male/Female

Male

Process Connection

1/2"-20 UNF, M14x1.5, M18x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel (15-5 PH)

Diaphragm / Sensor Material

Stainless steel (15-5 PH)

Filling Fluid

Mercury

Seal

N/A

Hygienic Version

NO

Electrical Connection

5-pin connector, 6-pin connector

Electrical Connection Details

Refer to the datasheet

Display

NO

Display Details

N/A

Weight

N/A

TESTS / APPROVALS
Scope Approvals

CE / European Community, NEPSI / China, RCQM / Global

Ship Approvals

N/A

Explosion Protection

N/A

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Chemical fiber equipment, Plastic and rubber manufacturing equipment, Plastic extruder machine