GENERAL INFORMATION |
Series / Product | Series
| Brand | Balluff
| Origin | Germany
| Series | Balluff – BSP
|
---|
|
PRESSURE SENSOR SPECIAL FEATURES |
Product Type | Pressure Transmitter
| Technology (Measuring Principle) | Ceramic measuring cell Stainless steel measuring cell
| Varieties | Flush Diaphragm, Vacuum / Compound
|
---|
|
MEASURING RANGES |
Reference Pressure | Gauge
| Pressure Unit | [bar]
| Pressure Range | -1 … 600 bar
| Pressure Range [bar] [Min] | -1
| Pressure Range [bar] [Max] | 600
| Pressure Range [psi] [Min] | -14.5
| Pressure Range [psi] [Max] | 8702.3
| Static Pressure [bar] [Max] | N/A
| Overpressure [bar] [Max] | N/A
| Positive Overpressure [bar] | N/A
| Negative Overpressure [bar] | N/A
| Burst Pressure [bar] [Min] | N/A
|
---|
|
PRESSURE SENSOR PERFORMANCE |
Accuracy | ≤ ± 0.5 %FS
| Accuracy Details | ±0.5 % FSO BFSL
| Non-linearity | N/A
| Non-linearity Details | N/A
| Long Term Stability | ≤ ± 0.3 %FS
| Long Term Stability Details | 0.3 % FSO/year
| TC Sensitivity | ≤ ± 0.3 %FS/10K
| TC Zero Point | ≤ ± 0.3 %FS/10K
| Adjustable | N/A
| Adjustability Details | N/A
| Resolution | ≤ 14 bits
| Sensitivity | N/A
| Response Time | < 1 ms, < 18 ms
| Response Time Details | ■ Response time max. 18 ms ■ Sampling rate: 1 ms
|
---|
|
ELECTRICAL SPECIFICATIONS |
Output Signal | 0 … 10 VDC, 4 … 20 mA, IO-Link interface, Switching Output
| Output Signal Details | Output as 4… 20 mA, 0 … 10 V or IO-Link with switching output (NPN / PNP)
| Supply Voltage | N/A
| Load Resistance | N/A
| Power Consumption | N/A
| Short-circuit Protection | YES
| Reverse Polarity Protection | YES
|
---|
|
ENVIROMENTAL CONDITIONS |
Media Temperature [°C] [Min] | -40
| Media Temperature [°C] [Max] | +125
| Ambient Temperature [°C] [Min] | -25
| Ambient Temperature [°C] [Max] | +85
| Storage Temperature [°C] [Min] | -40
| Storage Temperature [°C] [Max] | +85
| Compensated Temperature [°C] [Min] | 0
| Compensated Temperature [°C] [Max] | +70
| Ingress Protection | IP67, IP69K
| Vibration Resistance | 10 g, 25…2000 Hz
| Shock Resistance | 500 g, 1 ms
|
---|
|
GENERAL MECHANICAL SPECIFICATIONS |
Mounting | Flush Diaphragm, Threaded – Internal Diaphragm
| Process Connection Male/Female | Male
| Process Connection | 1/4" NPT, G 1/2", G 1/4", R 1/4", Tri-Clamp
| Process Connection Details | N/A
| With Damper (Puls-snubber) | N/A
| Process Connection Material | Stainless steel 1.4404 (316L), Stainless steel 1.4571 (316Ti)
| Diaphragm / Sensor Material | Ceramic, Stainless steel 1.4435 (316L), Stainless steel 1.4542 (17-4 PH / 630)
| Filling Fluid | N/A
| Seal | Welded, Without
| Hygienic Version | YES
| Electrical Connection | M12x1
| Electrical Connection Details | M12x1-Male, 4-pin, A-coded
| Display | NO
| Display Details | N/A
| Weight | Refer to the datasheet of products
|
---|
|
TESTS / APPROVALS |
Scope Approvals | c-UL-us / USA and Canada, CE / European Community, EAC / Eurasian Economic Community, UKCA / Great Britain
| Ship Approvals | N/A
| Explosion Protection | N/A
| EX Zone | N/A
| Other Approvals | WEEE
| SIL Qualification | N/A
|
---|
|
INDUSTRIES / APPLICATIONS |
Application | Food and beverage manufacturing, Hydrostatic level measurement, Laboratory and test, Pharmaceutical, Sterilization, Test and measurement, Water pressure control system
|
---|
|