GENERAL INFORMATION |
|
PRESSURE SENSOR SPECIAL FEATURES |
|
MEASURING RANGES |
|
PRESSURE SENSOR PERFORMANCE |
Accuracy | ≤ ± 0.065 %FS, ≤ ± 0.075 %FS
| Accuracy Details | ■ ±0.075% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability ■ 0.065% accuracy to 10:1 turndown ■ For spans less than 10:1, accuracy = ±[0.009(URL/SPAN)]% span
| Non-linearity | N/A
| Non-linearity Details | N/A
| Long Term Stability | ≤ ± 0.1 %FS
| Long Term Stability Details | Ranges 2–4: ±0.10 percent of URL for three years Range 1: ±0.10 percent of URL for one year
| TC Sensitivity | N/A
| TC Zero Point | N/A
| Adjustable | YES
| Adjustability Details | ■ Turndown: 10:1 ■ Zero and span values can be set anywhere within the range limits ■ Including local zero and span adjustments ■ Digital zero trim by Configuration buttons
| Resolution | N/A
| Sensitivity | N/A
| Response Time | < 145 ms
| Response Time Details | Total response time: 145 milliseconds Update rate: 22 times per second minimum
|
---|
|
ELECTRICAL SPECIFICATIONS |
Output Signal | 1 … 5 VDC HART®, 4 … 20 mA HART®, NAMUR
| Output Signal Details | ■ 4–20 mA dc/Digital HART Protocol ■ 1–5 Vdc Low Power/Digital HART Protocol
| Supply Voltage | N/A
| Load Resistance | N/A
| Power Consumption | N/A
| Short-circuit Protection | N/A
| Reverse Polarity Protection | YES
|
---|
|
ENVIROMENTAL CONDITIONS |
Media Temperature [°C] [Min] | -40
| Media Temperature [°C] [Max] | +121
| Ambient Temperature [°C] [Min] | -40
| Ambient Temperature [°C] [Max] | +85
| Storage Temperature [°C] [Min] | -46
| Storage Temperature [°C] [Max] | +110
| Compensated Temperature [°C] [Min] | N/A
| Compensated Temperature [°C] [Max] | N/A
| Ingress Protection | IP66, IP68, NEMA 4X
| Vibration Resistance | Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10–60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3g).
| Shock Resistance | N/A
|
---|
|
GENERAL MECHANICAL SPECIFICATIONS |
Mounting | Threaded – Internal Diaphragm
| Process Connection Male/Female | Female, Male
| Process Connection | 1/2"-14 NPT, Diaphragm seal, G 1/2", M20x1.5, PT 1/2", RC 1/4", Valve Manifold
| Process Connection Details | N/A
| With Damper (Puls-snubber) | NO
| Process Connection Material | Hastelloy® C-276 (2.4819), Stainless steel (316L)
| Diaphragm / Sensor Material | Hastelloy® C-276 (2.4819), Stainless steel (316L)
| Filling Fluid | Inert fluid, Silicon oil
| Seal | Buna-N®
| Hygienic Version | NO
| Electrical Connection | 1/2"-14 NPT Conduit entry, G 1/2" Conduit entry, M20x1.5 Conduit entry
| Electrical Connection Details | ½–14 NPT, M20 x 1.5 (CM20), or G½ female (PF ½ female) conduit entry
| Display | YES
| Display Details | ■ Fully configurable LCD display to display process variable, percent of range, and diagnostic messages ■ LCD display with local operator interface ■ LCD display, configured for engineering units
| Weight | Output code S and N: approximately 2.44 lb (1.11 kg)
|
---|
|
TESTS / APPROVALS |
Scope Approvals | ATEX / Europe, CE / European Community, Drinking Water System Components / NSF, EACEx / Eurasian Economic Community, FM / USA, HART | FieldComm Group / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NACE / International, NEPSI / China, TIIS / Japan
| Ship Approvals | ABS / USA, BV / Global, DNV-GL / Germany, LR / The UK
| Explosion Protection | Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"
| EX Zone | Zone 0, Zone 1
| Other Approvals | N/A
| SIL Qualification | N/A
|
---|
|
INDUSTRIES / APPLICATIONS |
Application | Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology
|
---|
|