نمایش 10–13 از 13 نتیجه

نمایش 9 24

ترانسمیتر فشار دیفرانسیل ABB 266MST

GENERAL INFORMATION
Series / Product

Series

Brand

ABB

Origin

Switzerland

Series

ABB – 266MST

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

N/A

Varieties

Differential, Explosion Proof (EX), Flush Diaphragm, High Accuracy

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[mbar], [bar], [inH2O], [psi], [kPa]

Pressure Range

-1 … 1 kPa to -10000 … 10000 kPa / -10 … 10 mbar to -100 … 100 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

100

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

1450.4

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.025 %FS, ≤ ± 0.04 %FS

Accuracy Details

0.04 % of calibrated span (optional, 0.025 %)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

■ ± 0.15 % of URL over a period of 10 years (± 0.05 % URL/year) ■ ± 0.3 % of URL over a period of 10 years (± 0.2 % URL/year)

TC Sensitivity

Refer to the datasheet

TC Zero Point

Refer to the datasheet

Adjustable

YES

Adjustability Details

Large turn down ratio of up to 100:1

Resolution

N/A

Sensitivity

N/A

Response Time

< 1000 ms, < 150 ms, < 40 ms, < 400 ms

Response Time Details

Time constant (63.2 % of total step response): ■ Sensors F to R: 150 ms ■ Sensor C: 400 ms ■ Sensor A: 1000 ms ■ Reaction time for all sensors: 40 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ HART digital communication and 4 to 20 mA ■ PROFIBUS PA ■ FOUNDATION Fieldbus ■ HART digital communication and 4 to 20 mA, SIL2 and SIL3 certified to IEC 61508

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+121

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-50

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP66, IP67, IP68, NEMA 4X

Vibration Resistance

Acceleration up to 2 g at frequencies of up to 1000 Hz (according to IEC 60068-2-6). Acceleration limited to 1 g for housing out of stainless steel.

Shock Resistance

In accordance with IEC 60068–2–27, Acceleration: 50 g, Duration: 11 ms

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, 1/4"-18 NPT, 7/16"-20 UNF, Flange

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Kynar®, Monel® 400, Stainless steel 1.4404 (316L), Stainless steel 1.4408 (316)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel 400® gold-plated, Monel® 400, Stainless steel 1.4435 (316L), Tantalum

Filling Fluid

Inert fluid, Silicon oil

Seal

N/A

Hygienic Version

N/A

Electrical Connection

Field housing with cable gland 1/2"-14 NPT, Field housing with cable gland M20x1.5, Fieldbus connector, Harting Han connector

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

• With integral LCD display • TTG (Through The Glass) integral digital LCD display

Weight

• (without options): Approximately 3.7 kg (8.2 lb); add 1.5 kg (3.3 lb) for stainless steel housing. • Add 650 g (1.5 lb) for packaging

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, FDA / USA, FM / USA, GOST / Russia, IECEx / Worldwide, NACE / International, NEPSI / China

Ship Approvals

ABS / USA, DNV / Germany, DNV-GL / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

Refer to the datasheet

Other Approvals

RoHS

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Application

DP closed vessel level measurement, Fuel storage, Laboratory and test, Liquid, steam and gas differential pressure measurement, Oil field equipment, Oil platforms, Oxygen level monitoring in cylinders, Pasty media, Potentially hazardous areas, Pressure monitoring in the hazardous areas, Viscous media

ترانسمیتر فشار رزمونت ROSEMOUNT 3051C

GENERAL INFORMATION
Series / Product

Series

Brand

ROSEMOUNT

Origin

USA

Series

ROSEMOUNT – 3051C Coplanar

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

N/A

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Differential, Gauge

Pressure Unit

[bar], [mbar], [psi], [inH2O]

Pressure Range

■ Gauge: -62.16 … 62.16 mbar to -0.97 … 137.89 bar ■ Absolute: 0 … 2.06 bar to 0 … 275.79 bar ■ Differential: -7.46 … 7.46 mbar to -137.89 … 137.89 bar

Pressure Range [bar] [Min]

-0.97

Pressure Range [bar] [Max]

275.79

Pressure Range [psi] [Min]

-14.2

Pressure Range [psi] [Max]

4000

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS, ≤ ± 0.065 %FS, ≤ ± 0.1 %FS

Accuracy Details

N/A

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.15 %URL, ≤ ± 0.2 %URL

Long Term Stability Details

15-year stability

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

Refer to the datasheet

Resolution

N/A

Sensitivity

N/A

Response Time

< 100 ms, < 255 ms, < 700 ms

Response Time Details

■ Total response time (Dead time+Time constant) ■ 4 – 20 mA HART® (Ranges 2-5: 100 ms, Range 1: 255 ms, Range 0: 700 ms)

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA, Wireless

Output Signal Details

■ 4–20 mA with digital signal based on HART® protocol, Configured for HART Revision 7 ■ FOUNDATION™ Fieldbus protocol

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-60

Media Temperature [°C] [Max]

+149

Ambient Temperature [°C] [Min]

-60

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-60

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP68, NEMA 4X

Vibration Resistance

Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10–60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3 g).

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Flush Diaphragm, Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

Flange, Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Monel 400® gold-plated, Monel® 400, Stainless steel (316L), Stainless steel (316L) gold-plated, Tantalum

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel 400® gold-plated, Monel® 400, Stainless steel (316L), Stainless steel (316L) gold-plated, Tantalum

Filling Fluid

Inert fluid, Silicon oil

Seal

Glass-filled PTFE, Graphite-filled PTFE

Hygienic Version

NO

Electrical Connection

1/2"-14 NPT Conduit entry, G 1/2" Conduit entry, M20x1.5 Conduit entry

Electrical Connection Details

■ M12, 4-pin, male connector (eurofast®) ■ A size mini, 4-pin, male connector (minifast®)

Display

YES

Display Details

■ LCD display with LOI (Only available with 4-20 mA HART output (code A) and PROFIBUS-PA (code W) ■ LCD display

Weight

■ Rosemount 3051 in lb. (kg): 6.0 (2.7) ■ Wireless in lb. (kg): 3.9 (1.8)

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CSA / Canada, FM / USA, IECEx / Worldwide, INMETRO / Brazil, NACE / International, TIIS / Japan

Ship Approvals

ABS / USA, BV / Global, DNV-GL / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

Zone 0, Zone 1, Zone 2

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار روزمونت ROSEMOUNT 3051T

GENERAL INFORMATION
Series / Product

Series

Brand

ROSEMOUNT

Origin

USA

Series

ROSEMOUNT – 3051T

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Field-proven piezoresistive sensor

Varieties

Absolute, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], [psi]

Pressure Range

■ Gauge: -5 … 5 psi to -14.7 … 20,000 psi / -344.74 … 344.74 mbar to -1.01 … 1378.95 bar ■ Absolute: 0 … 30 psi to 0 … 20,000 psi / 0 … 2.06 bar to 0 … 1378.95 bar

Pressure Range [bar] [Min]

-1.01

Pressure Range [bar] [Max]

1379

Pressure Range [psi] [Min]

-14.7

Pressure Range [psi] [Max]

20000

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS, ≤ ± 0.075 %FS

Accuracy Details

Refer to the datasheet

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.2 %URL

Long Term Stability Details

10-year stability of 0.2 percent of URL

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ Digital zero trim ■ Turndown: Up to 150:1

Resolution

N/A

Sensitivity

N/A

Response Time

< 100 ms, < 152 ms

Response Time Details

■ 4 – 20 mA HART®: 100 ms ■ FOUNDATION™ Fieldbus and PROFIBUS®PA Protocols: 152 ms ■ Update rate: 22 times per second

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA, Wireless

Output Signal Details

■ HART Revision 5 is the default HART output ■ WirelessHART® ■ Configured for HART Revision 5 ■ Configured for HART Revision 7

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+149

Ambient Temperature [°C] [Min]

-60

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-60

Storage Temperature [°C] [Max]

+110

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP66, IP68, NEMA 4X

Vibration Resistance

Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1: 1999 field or pipeline with high vibration level (10– 60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3g).

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, F250C (1/4" HP) Autoclave, Flange, G 1/2"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316) gold-plated, Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Filling Fluid

Fluorinert™ FC-43, Silicon oil

Seal

Glass-filled PTFE, Graphite-filled PTFE

Hygienic Version

NO

Electrical Connection

1/2"-14 NPT Conduit entry, G 1/2" Conduit entry, M20x1.5 Conduit entry

Display

YES

Display Details

■ LCD display with LOI (Only available with 4-20 mA HART output (code A) and PROFIBUS-PA (code W) ■ LCD display

Weight

■ Rosemount 3051 in lb. (kg): 3.0 (1.4) ■ Wireless in lb. (kg): 1.9 (0.86)

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, EACEx / Eurasian Economic Community, FM / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NACE / International, NEPSI / China, TIIS / Japan

Ship Approvals

ABS / USA, BV / Global, DNV-GL / Germany, LR / The UK

Explosion Protection

Intrinsic Safety "i" Flameproof Enclosure "d" Non-incendive "n" Dust Explosion Protection Through Housing "t"

EX Zone

Zone 0, Zone 1, Zone 2

Other Approvals

N/A

SIL Qualification

SIL2/3

INDUSTRIES / APPLICATIONS
Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار رزمونت ROSEMOUNT 2088

GENERAL INFORMATION
Series / Product

Series

Brand

ROSEMOUNT

Origin

USA

Series

ROSEMOUNT – 2088

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

Field-proven piezoresistive sensor

Varieties

Absolute, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], [psi]

Pressure Range

■ Gauge: -14.7 … 30 psi to -14.7 … 4000 psi / -1.01 … 2.1 bar to -1.01 … 275.8 bar ■ Absolute: 0 … 30 psi to 0 … 4000 psi / 0 … 2.1 bar to 0 … 275.8 bar

Pressure Range [bar] [Min]

-1.01

Pressure Range [bar] [Max]

275.8

Pressure Range [psi] [Min]

-14.7

Pressure Range [psi] [Max]

4000

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.065 %FS, ≤ ± 0.075 %FS

Accuracy Details

■ ±0.075% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability ■ 0.065% accuracy to 10:1 turndown ■ For spans less than 10:1, accuracy = ±[0.009(URL/SPAN)]% span

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Ranges 2–4: ±0.10 percent of URL for three years Range 1: ±0.10 percent of URL for one year

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ Turndown: 10:1 ■ Zero and span values can be set anywhere within the range limits ■ Including local zero and span adjustments ■ Digital zero trim by Configuration buttons

Resolution

N/A

Sensitivity

N/A

Response Time

< 145 ms

Response Time Details

Total response time: 145 milliseconds Update rate: 22 times per second minimum

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA HART®, NAMUR

Output Signal Details

■ 4–20 mA dc/Digital HART Protocol ■ 1–5 Vdc Low Power/Digital HART Protocol

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+121

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-46

Storage Temperature [°C] [Max]

+110

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP68, NEMA 4X

Vibration Resistance

Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10–60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3g).

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, Diaphragm seal, G 1/2", M20x1.5, PT 1/2", RC 1/4", Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Filling Fluid

Inert fluid, Silicon oil

Seal

Buna-N®

Hygienic Version

NO

Electrical Connection

1/2"-14 NPT Conduit entry, G 1/2" Conduit entry, M20x1.5 Conduit entry

Electrical Connection Details

½–14 NPT, M20 x 1.5 (CM20), or G½ female (PF ½ female) conduit entry

Display

YES

Display Details

■ Fully configurable LCD display to display process variable, percent of range, and diagnostic messages ■ LCD display with local operator interface ■ LCD display, configured for engineering units

Weight

Output code S and N: approximately 2.44 lb (1.11 kg)

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, Drinking Water System Components / NSF, EACEx / Eurasian Economic Community, FM / USA, HART | FieldComm Group / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NACE / International, NEPSI / China, TIIS / Japan

Ship Approvals

ABS / USA, BV / Global, DNV-GL / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

Zone 0, Zone 1

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology