در حال نمایش 4 نتیجه

نمایش 9 24

ترانسمیتر فشار تفاضلی یوکوگاوا EJX110A

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJX110A

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Differential, Explosion Proof (EX), High Accuracy

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kg/cm²]

Pressure Range

■ F: -50 to 50 mbar ■ L: -100 to 100 mbar ■ M: -1000 to 1000 mbar ■ H: -5000 to 5000 mbar ■ V: -5 to 140 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

140

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

2030.5

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.025 %FS, ≤ ± 0.04 %FS

Accuracy Details

■ Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) ■ ± 0.04% Accuracy (0.025% Accuracy option available)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

± 0.1% per 15 years Stability

TC Sensitivity

±(0.055% Span + 0.18% URL) ±(0.04% Span + 0.009% URL) ±(0.04% Span + 0.0125% URL)

TC Zero Point

±(0.055% Span + 0.18% URL) ±(0.04% Span + 0.009% URL) ±(0.04% Span + 0.0125% URL)

Adjustable

YES

Adjustability Details

■ Primary Variable: 200:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 150 ms, < 90 ms

Response Time Details

Response Time (Differential pressure): 90 ms for Wetted Parts material code S and L, except for Measuring span code F. 150 ms for Wetted Parts.

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5) ■ 4 to 20 mA DC (HART 5/HART 7), (GS 01C25T01-01EN) ■ FOUNDATION Fieldbus (GS 01C25T02-01EN) ■ PROFIBUS PA, (GS 01C25T04-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female

Process Connection

1/2" NPT, 1/4" NPT, Adapters, Cover Flange, Diaphragm seal, Rc 1/2", RC 1/4", Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel 316 (ASTM CF-8M), Stainless steel 316L (ASTM CF-3M), Super duplex Stainless steel

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel (316L), Stainless steel F316L (ASTM A182), Tantalum

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

Buna-N®, Fluororubber

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical LCD display, 6-digit unit display and bargraph. The indicator is configurable to display one or up to three of the following variables periodically.;

Weight

Refer to the datasheet

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, exida™ / Global, FM / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia, TÜV Rheinland / Global

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Mechanical engineering & Automation, Oil and gas, Petrochemical

Application

DP closed vessel level measurement, Fuel storage, Laboratory and test, Liquid, steam and gas differential pressure measurement, Oil field equipment, Oil platforms, Oxygen level monitoring in cylinders, Potentially hazardous areas, Viscous media

ترانسمیتر فشار ابسلوت یوکوگاوا EJX510A 

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJX510A

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Absolute, Explosion Proof (EX), Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ A: 0 to 29 psi / 0 to 2 bar ■ B: 0 to 290 psi / 0 to 20 bar ■ C: 0 to 1450 psi / 0 to 100 bar ■ D: 0 to 7200 psi / 0 to 500 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

500

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

7251.9

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS

Accuracy Details

Reference Accuracy of Calibrated Span (includes the effects of terminal-based linearity, hysteresis, and repeatability)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.2 %FS

Long Term Stability Details

± 0.2% per 15 years Stability

TC Sensitivity

±(0.15% of Span + 0.15% of URL)

TC Zero Point

±(0.15% of Span + 0.15% of URL)

Adjustable

YES

Adjustability Details

■ A Capsule: 25:1 ■ B, C, or D Capsule: 50:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 90 ms

Response Time Details

Response Time (All capsules): 90 ms, When software damping is set to zero and including dead time of 45 ms (nominal)

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5) ■ 4 to 20 mA DC (HART 5/HART 7), (GS 01C25T01-01EN) ■ FOUNDATION Fieldbus (GS 01C25T02-01EN) ■ PROFIBUS PA, (GS 01C25T04-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, Diaphragm seal, G 1/2", M20x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819)

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

Buna-N®, Fluororubber

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically;

Weight

■ Capsule A, B and C: 1.2 kg (2.6 lb)* ■ Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket.

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, FM / USA, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار گیج یوکوگاوا EJA530E

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJA530E

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ A: −14.5 to 29 psi / −1 to 2 bar ■ B: −14.5 to 290 psi / −1 to 20 bar ■ C: −14.5 to 1450 psi / −1 to 100 bar ■ D: −14.5 to 7200 psi / −1 to 500 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

500

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

7200

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.055 %FS

Accuracy Details

± 0.055% Accuracy

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

±0.1% Stability per 10 years

Long Term Stability Details

Stability (All normal operating condition): ±0.1% of URL per 10 years

TC Sensitivity

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

TC Zero Point

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

Adjustable

YES

Adjustability Details

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 90 ms

Response Time Details

Response Time (All capsules): 90 ms, When software damping is set to zero and including dead time of 45 ms (nominal)

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5/HART 7) ■ FOUNDATION Fieldbus (GS 01C31T02-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, Diaphragm seal, G 1/2", M20x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819)

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

Buna-N®, Fluororubber

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical LCD display, 6-digit unit display and bargraph. The indicator is configurable to display one or up to three of the following variables periodically.;

Weight

■ Capsule A, B and C: 1.2 kg (2.6 lb)* ■ Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket.

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, exida™ / Global, FM / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia, TÜV Rheinland / Global

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار یوکوگاوا EJA430E

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJA430E

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ H: −400 to 2000 inH2O / −1 to 5 bar ■ A: −14.5 to 500 psi / −1 to 35 bar ■ B: −14.5 to 2300 psi / −1 to 160 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

160

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

2300

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS, ≤ ± 0.055 %FS

Accuracy Details

■ Reference Accuracy of Calibrated Span (includes the eff ects of terminal-based linearity, hysteresis, and repeatability) ■ ±0.055% of Span ■ ±0.04% of Span (with /HAC option)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Stability (All normal operating condition): ±0.1% of URL per 10 years

TC Sensitivity

± (0.083% Span + 0.02% URL) ± (0.083% Span + 0.014% URL)

TC Zero Point

± (0.083% Span + 0.02% URL) ± (0.083% Span + 0.014% URL)

Adjustable

YES

Adjustability Details

■ Primary Variable: 100:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 150 ms, < 90 ms

Response Time Details

Response Time (All capsules): ■ 90 ms ■ 150 ms for H capsule with Wetted Parts Material code H, M, T, A, D, B and W.

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4-20 mA (BRAIN protocol) ■ 4-20 mA (HART 5/HART 7 protocol) ■ FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female

Process Connection

1/2" NPT, 1/4" NPT, Adapters, Cover Flange, Rc 1/2", RC 1/4", Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel 316 (ASTM CF-8M), Stainless steel 316L (ASTM CF-3M), Super duplex Stainless steel

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel (316L), Stainless steel F316L (ASTM A182), Tantalum

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

PTFE, Teflon-coated 316L SST

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical LCD display, 6-digit unit display and bargraph. The indicator is configurable to display one or up to three of the following variables periodically.;

Weight

[Installation code 7, 8 and 9] 2.8 kg(6.2 lb) for wetted parts material code S and L, without integral indicator, mounting bracket, and

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, FM / USA, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application