در حال نمایش 2 نتیجه

نمایش 9 24

ترانسمیتر فشار لبوم CI4100

GENERAL INFORMATION
Series / Product

Series

Brand

LABOM

Origin

Germany

Series

Labom – CI4100

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive Thin film

Varieties

Absolute, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[mbar], [bar], [Pa], [hPa], [kPa], [MPa], [g/cm2], [kg/cm2], [psi], [atm], [torr], [mmH2O], [mH2O], [inH2O], [ftH2O], [mmHg], [inHg]

Pressure Range

■ Gauge: -0.25 … 0.25 to -1 … 400 bar, 0 … 1 to 0 … 40 bar ■ Absolute: 0 … 1 to 0 … 16 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

400

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

5801.5

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.075 %FS, ≤ ± 0.1 %FS, ≤ ± 0.15 %FS

Accuracy Details

Reference accuracy: Per EN 60770 incl. non-linearity, hysteresis and repeatability refer to the adjusted measuring span:

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Long-term drift: Refer to nominal range ≤ 0.1 %/year

TC Sensitivity

Refer to the datasheet

TC Zero Point

Refer to the datasheet

Adjustable

YES

Adjustability Details

Up to a turndown of 100:1 the measuring span can be freely selected.

Resolution

0.5 µA

Sensitivity

N/A

Response Time

< 120 ms, < 50 ms

Response Time Details

Response time t90 at current output: ■ For 20 Hz measuring rate: typically 120 ms ■ For 100 Hz measuring rate: typically 50 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®

Output Signal Details

■ 4 … 20 mA / 2-wire ■ Digitale communication: HART® protocol, Version 7

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP67, IP69K

Vibration Resistance

Vibration resistance per EN 61298-3: 10 … 60 Hz: ± 0.35 mm, 60 … 1000 Hz: 5 g

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Process connection back, Process connection bottom

Process Connection Male/Female

Male

Process Connection

1/2" NPT, 1/4" NPT, G 1/2", G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4301 (304), Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L)

Diaphragm / Sensor Material

Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L), Stainless steel 1.4542 (17-4 PH / 630)

Filling Fluid

Dry measuring cell, FDA approved, Synthetic oil

Seal

NBR, Silicone

Hygienic Version

NO

Electrical Connection

Cable clamp, Cable gland, M12x1

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

■ High-resolution graphic display with backlight ■ 4-button operation ■ Freely configurable display modes ■ continuously rotatable by ± 170 (detent every 90°)

Weight

Approx. 1.4 Kg

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, HART | FieldComm Group / USA, IECEx / Worldwide

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2

INDUSTRIES / APPLICATIONS
Industry

Chemical, Mechanical engineering & Automation, Petrochemical

Application

Gas pressure measurement, Laboratory and test, Potentially hazardous areas, Pressure monitoring in the hazardous areas

ترانسمیتر فشار دیفرانسیل CI4340

GENERAL INFORMATION
Series / Product

Series

Brand

LABOM

Origin

Germany

Series

Labom – CI4340

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive

Varieties

Differential, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[mbar], [bar], [Pa], [hPa], [kPa], [MPa], [g/cm2], [kg/cm2], [psi], [atm], [torr], [mmH2O], [mH2O], [inH2O], [ftH2O], [mmHg], [inHg]

Pressure Range

-10 … 10 mbar to -16 … 16 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

16

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

232.1

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.07 %FS, ≤ ± 0.1 %FS

Accuracy Details

Reference accuracy: Per EN 61298-2 incl. non-linearity, hysteresis and repeatability refer to the adjusted measuring span.

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Long-term drift: ≤ 0.1 % within 5 years, refering to nominal range

TC Sensitivity

≤ ± 0.04% FS/10K

TC Zero Point

≤ ± 0.04% FS/10K

Adjustable

YES

Adjustability Details

■ Turndown up to 100:1 ■ Zero and span can be adjusted

Resolution

0.5 µA

Sensitivity

N/A

Response Time

< 200 ms

Response Time Details

■ Response time t90 at current output: typically 200 ms ■ Measuring rate up to 50 Hz

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®

Output Signal Details

■ 4 … 20 mA / 2-wire ■ Digitale communication: HART® protocol, Version 7

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP67, IP69K

Vibration Resistance

Vibration resistance per EN 61298-3: 10 … 60 Hz: ± 0.35 mm, 60 … 1000 Hz: 5 g

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, 1/2"-14 NPT, 1/4" NPT, 1/4"-18 NPT, 7/16"-20 UNF, Flange, Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel 1.4404 (316L), Stainless steel 1.4404 (316L), gold coating

Filling Fluid

Silicone oil

Seal

EPDM, FFKM

Hygienic Version

NO

Electrical Connection

Cable clamp, Cable gland, M12x1

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

■ High-resolution graphic display with backlight ■ 4-button operation ■ Freely configurable display modes ■ continuously rotatable by ± 170 (detent every 90°)

Weight

Approx. 2.9 Kg

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, HART | FieldComm Group / USA, IECEx / Worldwide, NACE / International

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2

INDUSTRIES / APPLICATIONS
Industry

Chemical, HVAC / HVAC&R, Petrochemical, Power, Water and wastewater

Application

DP closed vessel level measurement, Environmental Monitoring Systems, Filter monitoring, Power generation, Water pressure control system