در حال نمایش یک نتیجه

نمایش 9 24

ترانسمیتر فشار کرونه OPTIBAR PM 5060

GENERAL INFORMATION
Series / Product

Series

Brand

KROHNE

Origin

UK

Series

KROHNE – OPTIBAR PM 5060

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive Strain gauge Metallic – ceramic

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, High Accuracy, High Temperature, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], [MPa], [kPa], [psi]

Pressure Range

■ 0 … 100 mbar to 0 … 1000 bar / 0 … 1.45 to 0 … 14500 psi ■ Vacuum ranges

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

1000

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

14503.8

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.075 %FS, ≤ ± 0.1 %FS, ≤ ± 0.2 %FS

Accuracy Details

■ Reference accuracy acc. to DIN EN 60770 ■ Includes the non-linearity, hysteresis and repeatability under reference conditions

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS, ≤ ± 0.15 %FS, ≤ ± 0.35 %FS

Long Term Stability Details

■ Long-term stability acc. to DIN 16086 and IEC 60770-1 ■ per 1 year

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

Adjustment range of the zero / span adjustment in relation to the nominal range: • Zero (-20…+95%) • Span (-120…+120%) • Difference between zero and span: max. 120% of the nominal range

Resolution

Signal resolution: 0.3 µA

Sensitivity

N/A

Response Time

< 150 ms, < 200 ms, < 25 ms, < 50 ms, < 55 ms, < 80 ms

Response Time Details

Standard / IP68 (25bar): • Dead time ≤ 25 ms / ≤ 50 ms • Rise time 10…90% ≤ 55 ms / ≤ 150 ms • Step response time: ≤ 80 ms / ≤ 200 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4…20 mA / HART® version 7.3 ■ 3.8…20.5 mA / HART® version 7.3 (factory setting acc. to NAMUR recommendation) ■ Optional: 4 … 20 mA (passive)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-20

Media Temperature [°C] [Max]

+150

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-60

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, IP68, IP69K, NEMA 4X

Vibration Resistance

Vibration resistance acc. to EN 60068-2-6: 1…4 g at 5…200 Hz (vibration with resonance)

Shock Resistance

hock resistance acc. to EN 60068-2-27: 50 g, 2.3 ms (mechanical shock), 2 g with double chamber housing, stainless steel

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Flush Diaphragm, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, Clamp, DRD, Flange, G 1/2", Grooved union nut, NEUMO

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

2.4711 Elgiloy®, Gold-coated ceramic, Gold/rhodium-plated, Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Filling Fluid

Dry measuring cell, Halocarbon oil, Neobee® M-20, Silicon oil, Synthetic oil, KN 77 (FDA approved), White oil (FDA)

Seal

EPDM, FFKM, FKM, Klingersil® C-4400

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland M20x1.5

Electrical Connection Details

■ Cable entry: M20 x 1.5, 1/2-14 NPT ■ Cable gland: M20 x 1.5, 1/2-14 NPT ■ Blind plug: M20 x 1.5, 1/2-14 NPT

Display

YES

Display Details

■ Display element: Display with backlight turnable in 90° steps ■ Measured value indication: 5 digits (13×7 mm / 0.51×0.27") ■ Adjustment elements: 4 keys [OK], [->], [+], [ESC]

Weight

Refer to the datasheet

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, FDA / USA, FOUNDATION Fieldbus / International, HART | FieldComm Group / USA, IECEx / Worldwide, NAMUR, PED / Europe, PROFIBUS / Global, TÜV Rheinland / Global

Ship Approvals

N/A

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2/3

INDUSTRIES / APPLICATIONS
Industry

Basic materials, Chemical, Food and beverage, Life sciences and medical, Mechanical engineering & Automation, Oil and gas, Petrochemical, Water and wastewater

Application

Air pressure measurement, Food and beverage manufacturing, Gas pressure measurement, Hydrostatic level measurement, Level monitoring in open tanks, Liquid, steam and gas pressure measurement, Viscous media, Water pressure control system, Water treatment