GENERAL INFORMATION |
|
PRESSURE SENSOR SPECIAL FEATURES |
|
MEASURING RANGES |
|
PRESSURE SENSOR PERFORMANCE |
Accuracy | ≤ ± 0.04 %FS, ≤ ± 0.075 %FS
| Accuracy Details | Refer to the datasheet
| Non-linearity | N/A
| Non-linearity Details | N/A
| Long Term Stability | ≤ ± 0.2 %URL
| Long Term Stability Details | 10-year stability of 0.2 percent of URL
| TC Sensitivity | N/A
| TC Zero Point | N/A
| Adjustable | YES
| Adjustability Details | ■ Digital zero trim ■ Turndown: Up to 150:1
| Resolution | N/A
| Sensitivity | N/A
| Response Time | < 100 ms, < 152 ms
| Response Time Details | ■ 4 – 20 mA HART®: 100 ms ■ FOUNDATION™ Fieldbus and PROFIBUS®PA Protocols: 152 ms ■ Update rate: 22 times per second
|
---|
|
ELECTRICAL SPECIFICATIONS |
Output Signal | 1 … 5 VDC HART®, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA, Wireless
| Output Signal Details | ■ HART Revision 5 is the default HART output ■ WirelessHART® ■ Configured for HART Revision 5 ■ Configured for HART Revision 7
| Supply Voltage | N/A
| Load Resistance | N/A
| Power Consumption | N/A
| Short-circuit Protection | N/A
| Reverse Polarity Protection | N/A
|
---|
|
ENVIROMENTAL CONDITIONS |
Media Temperature [°C] [Min] | -40
| Media Temperature [°C] [Max] | +149
| Ambient Temperature [°C] [Min] | -60
| Ambient Temperature [°C] [Max] | +85
| Storage Temperature [°C] [Min] | -60
| Storage Temperature [°C] [Max] | +110
| Compensated Temperature [°C] [Min] | N/A
| Compensated Temperature [°C] [Max] | N/A
| Ingress Protection | IP65, IP66, IP68, NEMA 4X
| Vibration Resistance | Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1: 1999 field or pipeline with high vibration level (10– 60 Hz 0.21 mm displacement peak amplitude/60–2000 Hz 3g).
| Shock Resistance | N/A
|
---|
|
GENERAL MECHANICAL SPECIFICATIONS |
Mounting | Threaded – Internal Diaphragm
| Process Connection Male/Female | Female, Male
| Process Connection | 1/2"-14 NPT, F250C (1/4" HP) Autoclave, Flange, G 1/2"
| Process Connection Details | N/A
| With Damper (Puls-snubber) | NO
| Process Connection Material | Hastelloy® C-276 (2.4819), Stainless steel (316) gold-plated, Stainless steel (316L)
| Diaphragm / Sensor Material | Hastelloy® C-276 (2.4819), Stainless steel (316L)
| Filling Fluid | Fluorinert™ FC-43, Silicon oil
| Seal | Glass-filled PTFE, Graphite-filled PTFE
| Hygienic Version | NO
| Electrical Connection | 1/2"-14 NPT Conduit entry, G 1/2" Conduit entry, M20x1.5 Conduit entry
| Display | YES
| Display Details | ■ LCD display with LOI (Only available with 4-20 mA HART output (code A) and PROFIBUS-PA (code W) ■ LCD display
| Weight | ■ Rosemount 3051 in lb. (kg): 3.0 (1.4) ■ Wireless in lb. (kg): 1.9 (0.86)
|
---|
|
TESTS / APPROVALS |
Scope Approvals | ATEX / Europe, CE / European Community, EACEx / Eurasian Economic Community, FM / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NACE / International, NEPSI / China, TIIS / Japan
| Ship Approvals | ABS / USA, BV / Global, DNV-GL / Germany, LR / The UK
| Explosion Protection | Intrinsic Safety "i" Flameproof Enclosure "d" Non-incendive "n" Dust Explosion Protection Through Housing "t"
| EX Zone | Zone 0, Zone 1, Zone 2
| Other Approvals | N/A
| SIL Qualification | SIL2/3
|
---|
|
INDUSTRIES / APPLICATIONS |
Application | Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology
|
---|
|