GENERAL INFORMATION |
|
PRESSURE SENSOR SPECIAL FEATURES |
|
MEASURING RANGES |
|
PRESSURE SENSOR PERFORMANCE |
Accuracy | ≤ ± 0.04 %FS
| Accuracy Details | Reference Accuracy of Calibrated Span (includes the effects of terminal-based linearity, hysteresis, and repeatability)
| Non-linearity | N/A
| Non-linearity Details | N/A
| Long Term Stability | ≤ ± 0.2 %FS
| Long Term Stability Details | ± 0.2% per 15 years Stability
| TC Sensitivity | ±(0.15% of Span + 0.15% of URL)
| TC Zero Point | ±(0.15% of Span + 0.15% of URL)
| Adjustable | YES
| Adjustability Details | ■ A Capsule: 25:1 ■ B, C, or D Capsule: 50:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.
| Resolution | External zero is continuously adjustable with 0.01% incremental resolution of span.
| Sensitivity | N/A
| Response Time | < 90 ms
| Response Time Details | Response Time (All capsules): 90 ms, When software damping is set to zero and including dead time of 45 ms (nominal)
|
---|
|
ELECTRICAL SPECIFICATIONS |
Output Signal | 4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA
| Output Signal Details | ■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5) ■ 4 to 20 mA DC (HART 5/HART 7), (GS 01C25T01-01EN) ■ FOUNDATION Fieldbus (GS 01C25T02-01EN) ■ PROFIBUS PA, (GS 01C25T04-01EN)
| Supply Voltage | N/A
| Load Resistance | N/A
| Power Consumption | N/A
| Short-circuit Protection | N/A
| Reverse Polarity Protection | N/A
|
---|
|
ENVIROMENTAL CONDITIONS |
Media Temperature [°C] [Min] | -40
| Media Temperature [°C] [Max] | +120
| Ambient Temperature [°C] [Min] | -40
| Ambient Temperature [°C] [Max] | +85
| Storage Temperature [°C] [Min] | N/A
| Storage Temperature [°C] [Max] | N/A
| Compensated Temperature [°C] [Min] | N/A
| Compensated Temperature [°C] [Max] | N/A
| Ingress Protection | IP66, IP67, NEMA 4X
| Vibration Resistance | N/A
| Shock Resistance | N/A
|
---|
|
GENERAL MECHANICAL SPECIFICATIONS |
Mounting | Mounting Bracket, Threaded – Internal Diaphragm
| Process Connection Male/Female | Female, Male
| Process Connection | 1/2" NPT, Diaphragm seal, G 1/2", M20x1.5
| Process Connection Details | N/A
| With Damper (Puls-snubber) | NO
| Process Connection Material | Hastelloy® C-276 (2.4819), Stainless steel (316L)
| Diaphragm / Sensor Material | Hastelloy® C-276 (2.4819)
| Filling Fluid | Fluorinated® oil, Silicon oil
| Seal | Buna-N®, Fluororubber
| Hygienic Version | NO
| Electrical Connection | Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5
| Electrical Connection Details | Refer to the datasheet
| Display | YES
| Display Details | 5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically;
| Weight | ■ Capsule A, B and C: 1.2 kg (2.6 lb)* ■ Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket.
|
---|
|
TESTS / APPROVALS |
Scope Approvals | ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, FM / USA, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia
| Ship Approvals | ABS / USA, BV / Global, DNV / Germany, LR / The UK
| Explosion Protection | Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"
| EX Zone | N/A
| Other Approvals | N/A
| SIL Qualification | SIL 2, SIL 3
|
---|
|
INDUSTRIES / APPLICATIONS |
Industry | Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater
| Application | Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology
|
---|
|