نمایش 13–24 از 87 نتیجه

نمایش 9 24

ترانسمیتر فشار ابسلوت یوکوگاوا EJX510A 

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJX510A

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Absolute, Explosion Proof (EX), Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ A: 0 to 29 psi / 0 to 2 bar ■ B: 0 to 290 psi / 0 to 20 bar ■ C: 0 to 1450 psi / 0 to 100 bar ■ D: 0 to 7200 psi / 0 to 500 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

500

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

7251.9

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS

Accuracy Details

Reference Accuracy of Calibrated Span (includes the effects of terminal-based linearity, hysteresis, and repeatability)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.2 %FS

Long Term Stability Details

± 0.2% per 15 years Stability

TC Sensitivity

±(0.15% of Span + 0.15% of URL)

TC Zero Point

±(0.15% of Span + 0.15% of URL)

Adjustable

YES

Adjustability Details

■ A Capsule: 25:1 ■ B, C, or D Capsule: 50:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 90 ms

Response Time Details

Response Time (All capsules): 90 ms, When software damping is set to zero and including dead time of 45 ms (nominal)

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5) ■ 4 to 20 mA DC (HART 5/HART 7), (GS 01C25T01-01EN) ■ FOUNDATION Fieldbus (GS 01C25T02-01EN) ■ PROFIBUS PA, (GS 01C25T04-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, Diaphragm seal, G 1/2", M20x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819)

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

Buna-N®, Fluororubber

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically;

Weight

■ Capsule A, B and C: 1.2 kg (2.6 lb)* ■ Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket.

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, FM / USA, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار گیج یوکوگاوا EJA530E

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJA530E

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ A: −14.5 to 29 psi / −1 to 2 bar ■ B: −14.5 to 290 psi / −1 to 20 bar ■ C: −14.5 to 1450 psi / −1 to 100 bar ■ D: −14.5 to 7200 psi / −1 to 500 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

500

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

7200

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.055 %FS

Accuracy Details

± 0.055% Accuracy

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

±0.1% Stability per 10 years

Long Term Stability Details

Stability (All normal operating condition): ±0.1% of URL per 10 years

TC Sensitivity

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

TC Zero Point

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

Adjustable

YES

Adjustability Details

±(0.15% of Span + 0.15% of URL) ±(0.15% of Span + 0.15% of 50 MPa)

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 90 ms

Response Time Details

Response Time (All capsules): 90 ms, When software damping is set to zero and including dead time of 45 ms (nominal)

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4 to 20 mA (BRAIN) ■ 4 to 20 mA DC (HART 5/HART 7) ■ FOUNDATION Fieldbus (GS 01C31T02-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, Diaphragm seal, G 1/2", M20x1.5

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819)

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

Buna-N®, Fluororubber

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical LCD display, 6-digit unit display and bargraph. The indicator is configurable to display one or up to three of the following variables periodically.;

Weight

■ Capsule A, B and C: 1.2 kg (2.6 lb)* ■ Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket.

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, exida™ / Global, FM / USA, IECEx / Worldwide, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia, TÜV Rheinland / Global

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار یوکوگاوا EJA430E

GENERAL INFORMATION
Series / Product

Series

Brand

YOKOGAWA

Origin

Japan

Series

YOKOGAWA – EJA430E

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DPharp digital sensor

Varieties

Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[MPa], [kPa], [psi], [inH2O], [bar], [kgf/cm2]

Pressure Range

■ H: −400 to 2000 inH2O / −1 to 5 bar ■ A: −14.5 to 500 psi / −1 to 35 bar ■ B: −14.5 to 2300 psi / −1 to 160 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

160

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

2300

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.04 %FS, ≤ ± 0.055 %FS

Accuracy Details

■ Reference Accuracy of Calibrated Span (includes the eff ects of terminal-based linearity, hysteresis, and repeatability) ■ ±0.055% of Span ■ ±0.04% of Span (with /HAC option)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Stability (All normal operating condition): ±0.1% of URL per 10 years

TC Sensitivity

± (0.083% Span + 0.02% URL) ± (0.083% Span + 0.014% URL)

TC Zero Point

± (0.083% Span + 0.02% URL) ± (0.083% Span + 0.014% URL)

Adjustable

YES

Adjustability Details

■ Primary Variable: 100:1 ■ Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters.

Resolution

External zero is continuously adjustable with 0.01% incremental resolution of span.

Sensitivity

N/A

Response Time

< 150 ms, < 90 ms

Response Time Details

Response Time (All capsules): ■ 90 ms ■ 150 ms for H capsule with Wetted Parts Material code H, M, T, A, D, B and W.

ELECTRICAL SPECIFICATIONS
Output Signal

1 … 5 VDC HART®, 4 … 20 mA (BRAIN protocol), 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4-20 mA (BRAIN protocol) ■ 4-20 mA (HART 5/HART 7 protocol) ■ FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+120

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

N/A

Storage Temperature [°C] [Max]

N/A

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Mounting Bracket, Threaded – Internal Diaphragm

Process Connection Male/Female

Female

Process Connection

1/2" NPT, 1/4" NPT, Adapters, Cover Flange, Rc 1/2", RC 1/4", Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel 316 (ASTM CF-8M), Stainless steel 316L (ASTM CF-3M), Super duplex Stainless steel

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel, Stainless steel (316L), Stainless steel F316L (ASTM A182), Tantalum

Filling Fluid

Fluorinated® oil, Silicon oil

Seal

PTFE, Teflon-coated 316L SST

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland G 1/2", Field housing with cable gland M20x1.5

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

5-digit numerical LCD display, 6-digit unit display and bargraph. The indicator is configurable to display one or up to three of the following variables periodically.;

Weight

[Installation code 7, 8 and 9] 2.8 kg(6.2 lb) for wetted parts material code S and L, without integral indicator, mounting bracket, and

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, CSA / Canada, EAC / Eurasian Economic Community, FM / USA, INMETRO / Brazil, KCs (KOSHA) / South Korea, NEPSI / China, Regulatory Compliance Mark (RCM) / Australia

Ship Approvals

ABS / USA, BV / Global, DNV / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i", Non-incendive "n"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Industry

Chemical, Machine building, Mechanical engineering & Automation, Mining, minerals and metals, Oil and gas, Petrochemical, Water and wastewater

Application

Calibration & testing labs, Liquid, steam and gas pressure measurement, Oil field equipment, Oil platforms, Pressure monitoring in the hazardous areas, Process technology

ترانسمیتر فشار هاو HAWE DT 11

GENERAL INFORMATION
Series / Product

Series

Brand

HAWE Hydraulik SE

Origin

Germany

Series

HAWE – DT 11

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Strain gauge full bridge manufactured in thin-film technology as pressure measuring cell

Varieties

N/A

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar]

Pressure Range

■ 0 … 100 bar ■ 0 … 250 bar ■ 0 … 400 bar ■ 0 … 600 bar ■ 0 … 1000 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

1000

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

14503.8

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 1 %FS

Accuracy Details

Precision 1%

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

High long-term stability

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

NO

Adjustability Details

N/A

Resolution

N/A

Sensitivity

N/A

Response Time

< 6 ms

Response Time Details

Adjusting time (10 … 90%) tA: ≤ 6 ms

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 4 … 20 mA

Output Signal Details

■ 4 … 20 mA, two-wire system (limited to 25 mA) ■ 0 … 10 V DC, three-wire system, short-circuit proof

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

YES

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-30

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-30

Ambient Temperature [°C] [Max]

+100

Storage Temperature [°C] [Min]

-30

Storage Temperature [°C] [Max]

+100

Compensated Temperature [°C] [Min]

0

Compensated Temperature [°C] [Max]

+80

Ingress Protection

IP65

Vibration Resistance

in accordance with IEC 60068-2-6: 10 g

Shock Resistance

in accordance with IEC 60068-2-27: 500 g

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

YES

Process Connection Material

Stainless steel (316L), Stainless steel 1.4534 (13-8 PH)

Diaphragm / Sensor Material

Stainless steel (316L), Stainless steel 1.4534 (13-8 PH)

Filling Fluid

N/A

Seal

NBR

Hygienic Version

NO

Electrical Connection

DIN EN 175301-803-A

Electrical Connection Details

using male connector, in accordance with EN 175 301-803 A, max. 1.5 mm² Line diameter Ф 6-8 mm (in scope of delivery)

Display

NO

Display Details

N/A

Weight

Approx. 80 g

TESTS / APPROVALS
Scope Approvals

c-UL-us / USA and Canada

Ship Approvals

N/A

Explosion Protection

N/A

EX Zone

N/A

Other Approvals

RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Industry

Machine building, Mechanical engineering & Automation, Mobile machines

Application

Hydraulic systems, Mobile hydraulics, Plant control and monitoring, Test benches

ترانسمیتر فشار هاو HAWE DT 2

GENERAL INFORMATION
Series / Product

Series

Brand

HAWE Hydraulik SE

Origin

Germany

Series

HAWE – DT 2

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

DMS strain gauge full bridge manufactured using thin-film technology, as pressure measuring cell

Varieties

N/A

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar]

Pressure Range

■ 0 … 100 bar ■ 0 … 250 bar ■ 0 … 400 bar ■ 0 … 600 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

600

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

8702.3

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 1 %FS, ≤ ± 2 %FS

Accuracy Details

Characteristic curve deviation in the compensated area: ■ ≤ ±1% of the span for measuring ranges ≥ 40 bar ■ ≤ ±2% of the span for measuring ranges < 40 bar

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

High long-term stability

TC Sensitivity

≤ ±0.08% of the measuring end value / 10 K

TC Zero Point

≤ ±0.15% of the measuring end value / 10 K for measuring ranges ≥ 40 bar

Adjustable

NO

Adjustability Details

N/A

Resolution

N/A

Sensitivity

N/A

Response Time

< 2 ms

Response Time Details

Adjusting time (10 … 90%) tA: ≤ 2 ms

ELECTRICAL SPECIFICATIONS
Output Signal

0 … 10 VDC, 1 … 5 VDC, 4 … 20 mA

Output Signal Details

■ 4 … 20 mA, two-wire system ■ 0 … 10 V DC, three-wire system, short-circuit proof ■ 1 … 5 V DC, three-wire system

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

YES

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-30

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-30

Ambient Temperature [°C] [Max]

+100

Storage Temperature [°C] [Min]

-30

Storage Temperature [°C] [Max]

+100

Compensated Temperature [°C] [Min]

-40

Compensated Temperature [°C] [Max]

+100

Ingress Protection

IP67

Vibration Resistance

in accordance with IEC68-2: 20 g

Shock Resistance

in accordance with DIN EN 837: 500 g

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

YES

Process Connection Material

Stainless steel (316L), Stainless steel 1.4542 (17-4 PH / 630)

Diaphragm / Sensor Material

Stainless steel (316L), Stainless steel 1.4542 (17-4 PH / 630)

Filling Fluid

N/A

Seal

NBR

Hygienic Version

NO

Electrical Connection

M12x1

Electrical Connection Details

by means of line connector M12x1, 4-pole in accordance with EN 61076-2-101 (not included in scope of delivery)

Display

NO

Display Details

N/A

Weight

Approx. 70 g

TESTS / APPROVALS
Scope Approvals

CE / European Community, EAC / Eurasian Economic Community, GOST / Russia

Ship Approvals

N/A

Explosion Protection

N/A

EX Zone

N/A

Other Approvals

RoHS

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Industry

Machine building, Mechanical engineering & Automation, Mobile machines

Application

Hydraulic power unit, Hydraulic press machine, Hydraulic systems, Mobile hydraulics

ترانسمیتر فشار کرونه OPTIBAR PM 5060

GENERAL INFORMATION
Series / Product

Series

Brand

KROHNE

Origin

UK

Series

KROHNE – OPTIBAR PM 5060

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive Strain gauge Metallic – ceramic

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, High Accuracy, High Temperature, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], [MPa], [kPa], [psi]

Pressure Range

■ 0 … 100 mbar to 0 … 1000 bar / 0 … 1.45 to 0 … 14500 psi ■ Vacuum ranges

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

1000

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

14503.8

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.075 %FS, ≤ ± 0.1 %FS, ≤ ± 0.2 %FS

Accuracy Details

■ Reference accuracy acc. to DIN EN 60770 ■ Includes the non-linearity, hysteresis and repeatability under reference conditions

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS, ≤ ± 0.15 %FS, ≤ ± 0.35 %FS

Long Term Stability Details

■ Long-term stability acc. to DIN 16086 and IEC 60770-1 ■ per 1 year

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

Adjustment range of the zero / span adjustment in relation to the nominal range: • Zero (-20…+95%) • Span (-120…+120%) • Difference between zero and span: max. 120% of the nominal range

Resolution

Signal resolution: 0.3 µA

Sensitivity

N/A

Response Time

< 150 ms, < 200 ms, < 25 ms, < 50 ms, < 55 ms, < 80 ms

Response Time Details

Standard / IP68 (25bar): • Dead time ≤ 25 ms / ≤ 50 ms • Rise time 10…90% ≤ 55 ms / ≤ 150 ms • Step response time: ≤ 80 ms / ≤ 200 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ 4…20 mA / HART® version 7.3 ■ 3.8…20.5 mA / HART® version 7.3 (factory setting acc. to NAMUR recommendation) ■ Optional: 4 … 20 mA (passive)

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-20

Media Temperature [°C] [Max]

+150

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-60

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, IP68, IP69K, NEMA 4X

Vibration Resistance

Vibration resistance acc. to EN 60068-2-6: 1…4 g at 5…200 Hz (vibration with resonance)

Shock Resistance

hock resistance acc. to EN 60068-2-27: 50 g, 2.3 ms (mechanical shock), 2 g with double chamber housing, stainless steel

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Flush Diaphragm, Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, Clamp, DRD, Flange, G 1/2", Grooved union nut, NEUMO

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

2.4711 Elgiloy®, Gold-coated ceramic, Gold/rhodium-plated, Hastelloy® C-276 (2.4819), Stainless steel 1.4435 (316L)

Filling Fluid

Dry measuring cell, Halocarbon oil, Neobee® M-20, Silicon oil, Synthetic oil, KN 77 (FDA approved), White oil (FDA)

Seal

EPDM, FFKM, FKM, Klingersil® C-4400

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland M20x1.5

Electrical Connection Details

■ Cable entry: M20 x 1.5, 1/2-14 NPT ■ Cable gland: M20 x 1.5, 1/2-14 NPT ■ Blind plug: M20 x 1.5, 1/2-14 NPT

Display

YES

Display Details

■ Display element: Display with backlight turnable in 90° steps ■ Measured value indication: 5 digits (13×7 mm / 0.51×0.27") ■ Adjustment elements: 4 keys [OK], [->], [+], [ESC]

Weight

Refer to the datasheet

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, CE / European Community, FDA / USA, FOUNDATION Fieldbus / International, HART | FieldComm Group / USA, IECEx / Worldwide, NAMUR, PED / Europe, PROFIBUS / Global, TÜV Rheinland / Global

Ship Approvals

N/A

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2/3

INDUSTRIES / APPLICATIONS
Industry

Basic materials, Chemical, Food and beverage, Life sciences and medical, Mechanical engineering & Automation, Oil and gas, Petrochemical, Water and wastewater

Application

Air pressure measurement, Food and beverage manufacturing, Gas pressure measurement, Hydrostatic level measurement, Level monitoring in open tanks, Liquid, steam and gas pressure measurement, Viscous media, Water pressure control system, Water treatment

ترانسمیتر فشار لبوم CI4100

GENERAL INFORMATION
Series / Product

Series

Brand

LABOM

Origin

Germany

Series

Labom – CI4100

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive Thin film

Varieties

Absolute, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[mbar], [bar], [Pa], [hPa], [kPa], [MPa], [g/cm2], [kg/cm2], [psi], [atm], [torr], [mmH2O], [mH2O], [inH2O], [ftH2O], [mmHg], [inHg]

Pressure Range

■ Gauge: -0.25 … 0.25 to -1 … 400 bar, 0 … 1 to 0 … 40 bar ■ Absolute: 0 … 1 to 0 … 16 bar

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

400

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

5801.5

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.075 %FS, ≤ ± 0.1 %FS, ≤ ± 0.15 %FS

Accuracy Details

Reference accuracy: Per EN 60770 incl. non-linearity, hysteresis and repeatability refer to the adjusted measuring span:

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Long-term drift: Refer to nominal range ≤ 0.1 %/year

TC Sensitivity

Refer to the datasheet

TC Zero Point

Refer to the datasheet

Adjustable

YES

Adjustability Details

Up to a turndown of 100:1 the measuring span can be freely selected.

Resolution

0.5 µA

Sensitivity

N/A

Response Time

< 120 ms, < 50 ms

Response Time Details

Response time t90 at current output: ■ For 20 Hz measuring rate: typically 120 ms ■ For 100 Hz measuring rate: typically 50 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®

Output Signal Details

■ 4 … 20 mA / 2-wire ■ Digitale communication: HART® protocol, Version 7

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP67, IP69K

Vibration Resistance

Vibration resistance per EN 61298-3: 10 … 60 Hz: ± 0.35 mm, 60 … 1000 Hz: 5 g

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Process connection back, Process connection bottom

Process Connection Male/Female

Male

Process Connection

1/2" NPT, 1/4" NPT, G 1/2", G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4301 (304), Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L)

Diaphragm / Sensor Material

Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L), Stainless steel 1.4542 (17-4 PH / 630)

Filling Fluid

Dry measuring cell, FDA approved, Synthetic oil

Seal

NBR, Silicone

Hygienic Version

NO

Electrical Connection

Cable clamp, Cable gland, M12x1

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

■ High-resolution graphic display with backlight ■ 4-button operation ■ Freely configurable display modes ■ continuously rotatable by ± 170 (detent every 90°)

Weight

Approx. 1.4 Kg

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, HART | FieldComm Group / USA, IECEx / Worldwide

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2

INDUSTRIES / APPLICATIONS
Industry

Chemical, Mechanical engineering & Automation, Petrochemical

Application

Gas pressure measurement, Laboratory and test, Potentially hazardous areas, Pressure monitoring in the hazardous areas

ترانسمیتر فشار دیفرانسیل CI4340

GENERAL INFORMATION
Series / Product

Series

Brand

LABOM

Origin

Germany

Series

Labom – CI4340

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive

Varieties

Differential, Explosion Proof (EX), High Accuracy, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[mbar], [bar], [Pa], [hPa], [kPa], [MPa], [g/cm2], [kg/cm2], [psi], [atm], [torr], [mmH2O], [mH2O], [inH2O], [ftH2O], [mmHg], [inHg]

Pressure Range

-10 … 10 mbar to -16 … 16 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

16

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

232.1

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.07 %FS, ≤ ± 0.1 %FS

Accuracy Details

Reference accuracy: Per EN 61298-2 incl. non-linearity, hysteresis and repeatability refer to the adjusted measuring span.

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

≤ ± 0.1 %FS

Long Term Stability Details

Long-term drift: ≤ 0.1 % within 5 years, refering to nominal range

TC Sensitivity

≤ ± 0.04% FS/10K

TC Zero Point

≤ ± 0.04% FS/10K

Adjustable

YES

Adjustability Details

■ Turndown up to 100:1 ■ Zero and span can be adjusted

Resolution

0.5 µA

Sensitivity

N/A

Response Time

< 200 ms

Response Time Details

■ Response time t90 at current output: typically 200 ms ■ Measuring rate up to 50 Hz

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®

Output Signal Details

■ 4 … 20 mA / 2-wire ■ Digitale communication: HART® protocol, Version 7

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP67, IP69K

Vibration Resistance

Vibration resistance per EN 61298-3: 10 … 60 Hz: ± 0.35 mm, 60 … 1000 Hz: 5 g

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2" NPT, 1/2"-14 NPT, 1/4" NPT, 1/4"-18 NPT, 7/16"-20 UNF, Flange, Valve Manifold

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Stainless steel 1.4404 (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel 1.4404 (316L), Stainless steel 1.4404 (316L), gold coating

Filling Fluid

Silicone oil

Seal

EPDM, FFKM

Hygienic Version

NO

Electrical Connection

Cable clamp, Cable gland, M12x1

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

■ High-resolution graphic display with backlight ■ 4-button operation ■ Freely configurable display modes ■ continuously rotatable by ± 170 (detent every 90°)

Weight

Approx. 2.9 Kg

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, HART | FieldComm Group / USA, IECEx / Worldwide, NACE / International

Ship Approvals

N/A

Explosion Protection

Intrinsic Safety "i"

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

SIL 2

INDUSTRIES / APPLICATIONS
Industry

Chemical, HVAC / HVAC&R, Petrochemical, Power, Water and wastewater

Application

DP closed vessel level measurement, Environmental Monitoring Systems, Filter monitoring, Power generation, Water pressure control system

ترانسمیتر فشار وگا VEGABAR 82

GENERAL INFORMATION
Series / Product

Series

Brand

VEGA Grieshaber KG

Origin

Germany

Series

VEGA – VEGABAR 82

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

CERTEC®

Varieties

Absolute, Explosion Proof (EX), Flush Diaphragm, High Accuracy, High Temperature, Vacuum / Compound

MEASURING RANGES
Reference Pressure

Absolute, Gauge

Pressure Unit

[bar], [psi], [MPa]

Pressure Range

■ Gauge: -1 … 100 bar / -0.1 … 10 MPa / -14.5 … 1450 psig

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

100

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

1450

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.05 %FS, ≤ ± 0.1 %FS, ≤ ± 0.2 %FS

Accuracy Details

N/A

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ PLICSCOM ■ PC, PACTware and DTM ■ HART-Communicator ■ Software (e. g. AMS™, PDM) ■ Bluetooth

Resolution

N/A

Sensitivity

N/A

Response Time

N/A

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+150

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP68, IP69K, NEMA 4X

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Flush Diaphragm, Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

1/4"-18 NPT, Diaphragm seal

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Duplex (1.4462), Hastelloy® C-276 (2.4819), Monel, Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel (316L), Stainless steel 1.4404 (316L), Tantalum

Filling Fluid

N/A

Seal

Copper, EPDM, FFKM, PTFE

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland M20x1.5

Electrical Connection Details

N/A

Display

YES

Display Details

Display/Adjustment module PLICSCOM: • without • mounted • mounted; with Bluetooth, magnetic pen operation

Weight

N/A

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, C-CSA-US / USA and Canada, CSA / Canada, FM / USA, IECEx / Worldwide, VLAREM, WHG

Ship Approvals

ABS / USA, BV / Global, CCS / China, Class NK / Japan, DNV-GL / Germany, LR / The UK, RINA / Italy

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

Zone 0, Zone 0/1, Zone 1, Zone 2

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Delousing systems, Filter system for coarse dirt, Food and beverage manufacturing, Fresh water and pool water tanks

ترانسمیتر فشار دیفرانسیل وگا VEGADIF 85

GENERAL INFORMATION
Series / Product

Series

Brand

VEGA Grieshaber KG

Origin

Germany

Series

VEGA – VEGADIF 85

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Piezoresistive

Varieties

Differential, Explosion Proof (EX), High Accuracy

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[bar], [psi], [kPa]

Pressure Range

■ Gauge: 0.01 … 16 bar / 1 … 1600 kPa / 0.145 … 232 psi

Pressure Range [bar] [Min]

0.01

Pressure Range [bar] [Max]

16

Pressure Range [psi] [Min]

0.1

Pressure Range [psi] [Max]

232.1

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.065 %FS, ≤ ± 0.1 %FS

Accuracy Details

N/A

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

YES

Adjustability Details

■ PLICSCOM ■ PC, PACTware and DTM ■ HART-Communicator ■ Software (e. g. AMS™, PDM) ■ Bluetooth

Resolution

N/A

Sensitivity

N/A

Response Time

N/A

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA, 4 … 20 mA HART®, FOUNDATION™ Fieldbus, Modbus, PROFIBUS® PA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+85

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP66, IP67, IP68, IP69K, NEMA 4X, NEMA 6P

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/4"-18 NPT, Diaphragm seal

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Duplex (1.4462), Hastelloy® C-276 (2.4819), Monel, Stainless steel (316L)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Stainless steel (316L), Stainless steel 1.4404 (316L), Tantalum

Filling Fluid

N/A

Seal

Copper, EPDM, FFKM, PTFE

Hygienic Version

NO

Electrical Connection

Field housing with cable gland 1/2" NPT, Field housing with cable gland M20x1.5

Electrical Connection Details

N/A

Display

YES

Display Details

• Display/adjustment module PLICSCOM • VEGADIS 81 • VEGADIS 82

Weight

N/A

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, C-CSA-US / USA and Canada, FM / USA, GOST-B / Belarus, GOST-K / Kazakhstan, GOST-R / Russia, IECEx / Worldwide, INMETRO / Brazil, UkrSEPRO / Ukraine, WHG

Ship Approvals

DNV-GL / Germany

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

Zone 0, Zone 0/1, Zone 1, Zone 2

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

DP closed vessel level measurement, Fuel storage, Laboratory and test, Liquid, steam and gas differential pressure measurement, Oil field equipment, Oil platforms, Pasty media, Pressure monitoring in the hazardous areas, Viscous media

ترانسمیتر و سوئیچ فشار وگا VEGABAR 14

GENERAL INFORMATION
Series / Product

Series

Brand

VEGA Grieshaber KG

Origin

Germany

Series

VEGA – VEGABAR 14

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Electronic Pressure Switch, Pressure Transmitter

Technology (Measuring Principle)

Ceramic CERTEC® measuring cell

Varieties

Vacuum / Compound

MEASURING RANGES
Reference Pressure

Gauge

Pressure Unit

[bar], [psi], [kPa]

Pressure Range

■ Gauge: -1 … 60 bar / -100 … 6000 kPa / -14.5 … 870 psig

Pressure Range [bar] [Min]

-1

Pressure Range [bar] [Max]

60

Pressure Range [psi] [Min]

-14.5

Pressure Range [psi] [Max]

870.2

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.3 %FS

Accuracy Details

N/A

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

N/A

TC Sensitivity

N/A

TC Zero Point

N/A

Adjustable

NO

Adjustability Details

N/A

Resolution

N/A

Sensitivity

N/A

Response Time

N/A

Response Time Details

N/A

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA

Output Signal Details

N/A

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

N/A

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+100

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+80

Storage Temperature [°C] [Min]

-40

Storage Temperature [°C] [Max]

+80

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP67

Vibration Resistance

N/A

Shock Resistance

N/A

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Male

Process Connection

1/2" NPT, 1/4" NPT, G 1/2", G 1/4"

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

PVDF, Stainless steel (316L)

Diaphragm / Sensor Material

Duplex (1.4462), Sapphire-ceramic®

Filling Fluid

N/A

Seal

EPDM, FFKM, FKM

Hygienic Version

NO

Electrical Connection

Cable outlet, DIN EN 175301-803-A, M12x1

Electrical Connection Details

The housing is equipped with plug connector according to ISO 4400, M12 x 1 or with direct cable outlet. It is available with protection ratings up to IP 67.

Display

NO

Display Details

N/A

Weight

N/A

TESTS / APPROVALS
Scope Approvals

N/A

Ship Approvals

ABS / USA, DNV-GL / Germany, LR / The UK

Explosion Protection

N/A

EX Zone

N/A

Other Approvals

N/A

SIL Qualification

N/A

INDUSTRIES / APPLICATIONS
Application

Air conditioning systems, Compressor, Hydrostatic level measurement, Vacuum pressure measurement

ترانسمیتر فشار دیفرانسیل ABB 266MST

GENERAL INFORMATION
Series / Product

Series

Brand

ABB

Origin

Switzerland

Series

ABB – 266MST

PRESSURE SENSOR SPECIAL FEATURES
Product Type

Pressure Transmitter

Technology (Measuring Principle)

N/A

Varieties

Differential, Explosion Proof (EX), Flush Diaphragm, High Accuracy

MEASURING RANGES
Reference Pressure

Differential

Pressure Unit

[mbar], [bar], [inH2O], [psi], [kPa]

Pressure Range

-1 … 1 kPa to -10000 … 10000 kPa / -10 … 10 mbar to -100 … 100 bar

Pressure Range [bar] [Min]

0

Pressure Range [bar] [Max]

100

Pressure Range [psi] [Min]

0

Pressure Range [psi] [Max]

1450.4

Static Pressure [bar] [Max]

N/A

Overpressure [bar] [Max]

N/A

Positive Overpressure [bar]

N/A

Negative Overpressure [bar]

N/A

Burst Pressure [bar] [Min]

N/A

PRESSURE SENSOR PERFORMANCE
Accuracy

≤ ± 0.025 %FS, ≤ ± 0.04 %FS

Accuracy Details

0.04 % of calibrated span (optional, 0.025 %)

Non-linearity

N/A

Non-linearity Details

N/A

Long Term Stability

N/A

Long Term Stability Details

■ ± 0.15 % of URL over a period of 10 years (± 0.05 % URL/year) ■ ± 0.3 % of URL over a period of 10 years (± 0.2 % URL/year)

TC Sensitivity

Refer to the datasheet

TC Zero Point

Refer to the datasheet

Adjustable

YES

Adjustability Details

Large turn down ratio of up to 100:1

Resolution

N/A

Sensitivity

N/A

Response Time

< 1000 ms, < 150 ms, < 40 ms, < 400 ms

Response Time Details

Time constant (63.2 % of total step response): ■ Sensors F to R: 150 ms ■ Sensor C: 400 ms ■ Sensor A: 1000 ms ■ Reaction time for all sensors: 40 ms

ELECTRICAL SPECIFICATIONS
Output Signal

4 … 20 mA HART®, FOUNDATION™ Fieldbus, PROFIBUS® PA

Output Signal Details

■ HART digital communication and 4 to 20 mA ■ PROFIBUS PA ■ FOUNDATION Fieldbus ■ HART digital communication and 4 to 20 mA, SIL2 and SIL3 certified to IEC 61508

Supply Voltage

N/A

Load Resistance

N/A

Power Consumption

N/A

Short-circuit Protection

N/A

Reverse Polarity Protection

YES

ENVIROMENTAL CONDITIONS
Media Temperature [°C] [Min]

-40

Media Temperature [°C] [Max]

+121

Ambient Temperature [°C] [Min]

-40

Ambient Temperature [°C] [Max]

+85

Storage Temperature [°C] [Min]

-50

Storage Temperature [°C] [Max]

+85

Compensated Temperature [°C] [Min]

N/A

Compensated Temperature [°C] [Max]

N/A

Ingress Protection

IP65, IP66, IP67, IP68, NEMA 4X

Vibration Resistance

Acceleration up to 2 g at frequencies of up to 1000 Hz (according to IEC 60068-2-6). Acceleration limited to 1 g for housing out of stainless steel.

Shock Resistance

In accordance with IEC 60068–2–27, Acceleration: 50 g, Duration: 11 ms

GENERAL MECHANICAL SPECIFICATIONS
Mounting

Threaded – Internal Diaphragm

Process Connection Male/Female

Female, Male

Process Connection

1/2"-14 NPT, 1/4"-18 NPT, 7/16"-20 UNF, Flange

Process Connection Details

N/A

With Damper (Puls-snubber)

NO

Process Connection Material

Kynar®, Monel® 400, Stainless steel 1.4404 (316L), Stainless steel 1.4408 (316)

Diaphragm / Sensor Material

Hastelloy® C-276 (2.4819), Monel 400® gold-plated, Monel® 400, Stainless steel 1.4435 (316L), Tantalum

Filling Fluid

Inert fluid, Silicon oil

Seal

N/A

Hygienic Version

N/A

Electrical Connection

Field housing with cable gland 1/2"-14 NPT, Field housing with cable gland M20x1.5, Fieldbus connector, Harting Han connector

Electrical Connection Details

Refer to the datasheet

Display

YES

Display Details

• With integral LCD display • TTG (Through The Glass) integral digital LCD display

Weight

• (without options): Approximately 3.7 kg (8.2 lb); add 1.5 kg (3.3 lb) for stainless steel housing. • Add 650 g (1.5 lb) for packaging

TESTS / APPROVALS
Scope Approvals

ATEX / Europe, FDA / USA, FM / USA, GOST / Russia, IECEx / Worldwide, NACE / International, NEPSI / China

Ship Approvals

ABS / USA, DNV / Germany, DNV-GL / Germany, LR / The UK

Explosion Protection

Dust Explosion Protection Through Housing "t", Flameproof Enclosure "d", Intrinsic Safety "i"

EX Zone

Refer to the datasheet

Other Approvals

RoHS

SIL Qualification

SIL 2, SIL 3

INDUSTRIES / APPLICATIONS
Application

DP closed vessel level measurement, Fuel storage, Laboratory and test, Liquid, steam and gas differential pressure measurement, Oil field equipment, Oil platforms, Oxygen level monitoring in cylinders, Pasty media, Potentially hazardous areas, Pressure monitoring in the hazardous areas, Viscous media